    Fluke 1625 Advanced Earth / Ground Tester Geo Kit
    Automatic Frequency Control (AFC) – identifies existing interference and chooses a measurement frequency to minimize its effect, providing a more accurate earth ground value.
    Includes Hard Carrying Case & Accessories As Listed Above!


    Working Condition: Excellent
    Condition: Refurbished
    Calibrated: Yes
    Warranty: 1 YEAR WARRANTY


    The Fluke 1625 is distinctive earth ground testers that can perform all four types of earth ground measurement. Specifically, the Fluke 1625 tester is able to measure earth ground loop resistances using only clamps – called Stakeless testing. This method doesn’t require the use of earth ground stakes or the disconnection of ground rods.
    Testing Methods
    • 3- and 4-Pole Fall of Potential – standard earth ground testing using two ground stakes
    • Selective testing – without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp.
    • Stakeless testing – innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance.
    The Fluke 1625 offers these advanced features
    • Automatic Frequency Control (AFC) – identifies existing interference and chooses a measurement frequency to minimize its effect, providing a more accurate earth ground value.
    • R* measurement – calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to-earth ground would see.
    • Adjustable limits – for quick test result verification.

    Features:
    • 3- and 4-pole earth ground measurement
    • 4-Pole soil resistivity testing
    • 2-pole resistance measurement AC
    • 2- and 4-pole resistance measurement DC
    • Selective testing, no disconnection of ground conductor (1 clamp)
    • Stakeless testing, quick ground loop testing (2 clamps)
    • Earth impedance measurement at 55 Hz
    • Automatic frequency control (AFC) (94, 105, 111, 128 Hz)
    • Measuring voltage switchable 20/48V
    • Programmable limits, settings
    • Continuity with buzzer


    Specifications:
    RA 3-pole ground resistance measurement (IEC 1557-5)
    Measuring Voltage
     Vm = 20/48 V ac
    Short circuit current
     250 mA ac
    Measure frequency
     94, 105, 111, 128Hz
    Resolution
     0.001 Ω to 100 Ω
    Measuring range
     0.001 Ω to 299.9 kΩ
    Intrinsic error
     ± (2 % of reading + 2 d)
    Operating error
     ± (5 % of reading + 5 d)
    RA 4-pole ground resistance measurement (IEC 1557-5)
    Measuring Voltage
     Vm = 20/48 V ac
    Short circuit current
     250 mA ac
    Measure frequency
     94, 105, 111, 128Hz
    Resolution
     0.001 Ω to 100 Ω
    Measuring range
     0.001 Ω to 299.9 kΩ
    Intrinsic error
     ± (2 % of reading + 2 d)
    Operating error
     ± (5 % of reading + 5 d)
    RA 3-pole ground resistance measurement with current clamp
    Measuring Voltage
     Vm = 20/48 V ac
    Short circuit current
     250 mA ac
    Measure frequency
     94, 105, 111, 128Hz
    Resolution
     0.001 Ω to 10 Ω
    Measuring range
     0.001 Ω to 29.99 kΩ
    Intrinsic error
     ± (7 % of reading + 2 d)
    Operating error
     ± (10 % of reading + 5 d)
    RA 4-pole selective ground resistance measurement with current clamp
    Measuring Voltage
     Vm = 20/48 V ac
    Short circuit current
     250 mA ac
    Measure frequency
     94, 105, 111, 128Hz
    Resolution
     0.001 Ω to 10 Ω
    Measuring range
     0.001 Ω to 29.99 kΩ
    Intrinsic error
     ± (7 % of reading + 2 d)
    Operating error
     ± (10 % of reading + 5 d)
    Stakeless ground loop measurement
    Measuring Voltage
     Vm = 20/48 V ac
    Measure frequency
     94, 105, 111, 128Hz
    Noise current (Iext)
     Max. Iext = 3 A
    Resolution
     0.001 Ω to 10 Ω
    Measuring range
     0.001 Ω to 29.99 kΩ
    Intrinsic error
     ± (7 % of reading + 2 d)
    Operating error
     ± (10 % of reading + 5 d)
    Environmental Specifications
    Working temperature
     -10 °C to +50 °C
    Operating Temperature
     0 °C to +35 °C
    Nominal temperature
     +18 °C to +28 °C
    Storage Temperature
     -30 °C to +60 °C
    Climatic class
     C1 (IEC 654-1), -5 °C to + 45 °C, 5 % to 95 % RH
    Protection type
     IP56 for case, IP40 for battery door according to EN 60529
    Safety Specifications
    Safety Rating
     CAT II, 300 V
    Mechanical & General Specifications
    Display
     2999 Digit LCD – 7 segment liquid crystal display with special symbols and backlight
    Size
     133 mm x 187 mm x 250 mm
    Weight
    Fluke 1623 + 1625 1.1 kg (including batteries)
    Warranty
     90 Days
    Battery Life
     Typical 3000 measurements (RE+RH ≤ 1 kΩ)
     Typical 6000 measurements (RE+RH ≤ 10 kΩ)